Home » Shop » Other Test Meters & Detectors » Thermal Dispersion Flow Transmitter 90

Thermal Dispersion Flow Transmitter 90

Original price was: $4,088.25.Current price is: $3,132.59.

Sale!

69 in stock

SKU: TDT-WT-202 Category:

EXAMPLE

TDT

W

S

1

1

1

Series TDT-WS-111 Thermal Dispersion Transmitter, water base, 316SS, 0-1.64 ft/s (0-0.5 m/s), 10.28″ (261 mm) extension, 1 flow output

SERIES

TDT

 

 

 

 

 

Thermal Dispersion Transmitter

BASE TYPE

 

W
L

 

 

 

 

Water Based Fluids
Oil Based Fluids

WETTED MATERIAL

 

 

S
T

 

 

 

316 SS
Titanium

RANGE

 

 

 

1
2
3
4
5

 

 

0-1.64 ft/s (0-0.5 m/s)
0-3.28 ft/s (0-1 m/s)
0-6.56 ft/s (0-2 m/s)
0-9.87 ft/s (0-3 m/s)
0-12.47 ft/s (0-3.8 m/s)

EXTENSION

 

 

 

 

0
1
2

 

None
+10.28″ (+261 mm)
+15.75″ (+400 mm)

OUTPUT

 

 

 

 

 

1
2

1 flow output
1 flow output plus one temperature output

The Series TDT is an excellent alternative to turbine and paddlewheel insertion flow meters, with the ability to deliver high accuracy over a wide range of pipe sizes. This unit has the same insertion mounting into a 1-1/2″ NPT but no moving parts to wear, break, or clog. This transmitter has available extensions that can be used for pipes sized up to 75″ in diameter. The TDT Dispersion Transmitter measures even very low flow rates due to the applied calorimetric principle, and can be used for the metering of all fluid media such as: water, oil, aggressive media, paste, glue, sludge, grease, etc. Optional titanium allows this transmitter to be used with an even wider range of corrosive media, and the optional output allows the user to measure both flow and temperature. When deciding on the correct length, use the 1/7th law (the TDT’s probe length needs to measure 1/7th of the pipe diameter).

 

PRINCIPLES OF OPERATION
The sensor head of the Thermal Dispersion Transmitter contains two PT-resistors. One of them is measuring the temperature of the media, while the other is heated by an attached heating resistor. The temperature difference between the two PT-resistors is predetermined and a control circuit keeps this temperature difference constant. The flow of the media cools the heated PT-resistor proportional to the speed of the flow, this results in a linear output signal proportional to the flow speed.

 

Service: Water, oil, compatible liquids, paste, glue, sludge and grease. Wetted Materials: 316 SS, optional titanium.
Flow Range: Flow Range: Min: 0 to 0.66 ft/s (0 to 20 cm/s); Max: See Catalog page.
Temperature Range: (For optional output only) 32 to 212°F (0 to 100°C).
Accuracy: <3% of full range.
Repeatability: <1%.
Response Time: 10 seconds.
Temperature Limits: Process: 32 to 176°F (0 to 80°C); Ambient: -4 to 160°F (-20 to 70°C).
Pressure Limits: 261 psi (18 bar).
Process Connections: 1-1/2″ male NPT.
Signal: 4 to 20 mA for flow, optional 4 to 20 mA for temperature.
Power Requirements: 24 VDC +10 to 15%.
Resistive Load: 0 to 600 Ω. Current Consumption: Approx. 100 to 200 mA (max. flow).
Electrical Connection: 6.5 ft (2 m) molded oilflex cable with three 21 AWG (0.5 sq mm) wires.
Enclosure Rating: NEMA 4X (IP65).
Weight: 2 lb (907 g).